Skip to content

Scenario 4 - State of Health

Date: Monday 8 November 2027, 1800 Local (0200Z Tuesday) Site: SANDSTORM (SS-01), transportable X-band EA site, high desert Operator on Console: You - contractor, second shift Crew Chief: MSgt Delgado (maintenance tent, radio on channel 2) Mission Direction: 9 EWS ops floor, callsign RAMPART

Primary terminal still down; 0205Z contact is ours again. Monitor is on the bird from last night, receiver 3 on 1625, modem 1 still on 1200. Chain cold.

TALON-2 came out of eclipse at 0120Z. The battery heater runs through eclipse exit and cycles off on its own at 20 °C. Rotterdam’s note says it did not last time and they are watching it. So watch it.

Command stack has the TCS heater commands loaded. Do not send anything you cannot verify on the panel.

  • Delgado (turnover, 1745)

Signal RF (MHz) LO (MHz) IF (MHz) Notes
TT&C uplink 8,200 7,000 (BUC, low-side) 1,200 H-pol; modem 1 already tuned
Telemetry / beacon downlink 7,300 8,925 (LNB, high-side) 1,625 V-pol; receiver 3, monitor chain
Contact window - - - T+5:00 to T+40:00 mission elapsed

Two kinds of thing move on a telemetry panel, and the whole shift is telling them apart.

Transient Trend
What it looks like A channel departs and returns on its own A channel departs and keeps going
Cause Usually none visible; the spacecraft absorbed something Usually visible in the channel next to it
Rate to harm Never gets there Reaches a limit inside the window
What you do Log the time and the peak; it becomes a point in a long-term trend Name it, call it, command it, verify it

Tonight’s transient: reaction wheel 1 to ~5200 rpm for a minute at T+4:00 - a momentum bump, unloaded on its own. Tonight’s trend: battery temperature climbing about three degrees a minute from T+7:00 with heater state ON beside it, forty minutes after eclipse exit. At that rate the battery is at the 40 °C red limit inside three minutes of the yellow crossing.

Step Where What you see
HPA up, modem 1 keyed TX Chain Chain ready inside the window
TCS-HTR-OFF TT&C console ACK - receipt, not execution
Heater state Telemetry tab OFF on the next frame - the command executed
Battery temperature Telemetry tab Turns over and comes back inside limits over the next few minutes - the command fixed what you sent it for

A command is verified twice: the direct effect (the state it was meant to change) and the reason you sent it (the trend it was meant to stop). Log both times. Then chain cold before the log entry.

Section Line
Contact The transient with its time and peak; the trend with its rate and cause; the call; the command and its ACK; the verification, both halves; the chain state; the report raised